
We raised the bar on quality control through our exclusive concept of
Quality Cado, a continuously charged commitment to excellence.
Quality Cado is more than just a review of the production procss.
It begins with our first conversation and flows non stop until every detail
of customer satisfaction and product development has been closed.
Never a shortcut, never an oversight
That's the Cado Way

ASSEMBLY AND TEST AREA, Plant 2
2 - POWER SOURCE
Elgar AC Power Source
OUTPUT SIGNAL AMPLITUDE: 2V RMS
HARMONIC DISTORTION : LESS THAN 0.025% OF OUTPUT 45 HRTZ TO 5 KHZ
FREQUENCY RANGES: X1 45 HZ TO 99.99 HZ
X10 45 HZ TO 999.99 HZ
IDEAL FOR GENERAL PURPOSE TEST APPLICATIONS, AS WELL AS ATE SYSTEMS AND AVIONICS TESTING.
PROGRAMMABLE VIE THE IEEE 488 GENERAL PURPOSE INTERFACE BUS (GPIB)
AC POWER AT PRECISE FREQUENCIES FOR TESTING, MOTOR OPERATION, AND FREQUENCY CONVERSION
OUTPUT VOLTAGE RANGES FROM: 0 TO 65 VAC
0 TO 130 VAC
0 TO 260 VAC
THE POWER SOURCE CAN BE CONFIGURED FOR A 115, 208, OR 230 VAC IMPUTE47 - 63 HZ, SINGLE PHASE
STACO TYPE L501 POWER SOURCE
3 - DUAL DISPLAY MULTI METER
FLUKE TRUE RMS 5-DIGIT DMM
5 DIGIT 100,000 COUNT DMM
MEASUREMENT RATES OF 2.5, 5, OR 20 READINGS PER SECOND
READOUTS SHOW BOTH HI/LO/PASS EVALUATION AND MEASURED VALUE
21 REFERENCE IMPEDANCE FROM 2 OHMS TO 8000 OHMS. FOR 2,4,8 AND 16 OHM IMPEDANCE
ADDITIONAL FEATURES INCLUDE TOUCH-HOLD FUNCTION, RELATIVE REFERENCE, MIN/MAX MODE,AUDIBLE CONTINUITY AND DIODE TESTS.
2 - OSCILLOSCOPE
TEKTRONIKS TD 200 SERIES
1 GS/S SAMPLE RATE
WAVEFORM AND SET UP MEMORIES
SAMPLING AT 10 TO 16 TIMES THEIR BANDWIDTHS ON BOTH CHANNELS
DIGITAL STORAGE TECHNOLOGY
FIVE AUTOMATIC MEASUREMENTS PROVIDE QUICK EVALUATION OF ADVANCED SCOPE OPERATIONS 100 MHZ BAND WITH
1 - ASSOCIATED RESEARCH HYPOT & GROUND TEST SET
MANUFACTURING AND PRODUCTION LINE TESTING OF COMMERCIAL PRODUCTS TO MEET UL, CSA, VDE, BSI, AND IEC REQUIREMENTS
WHERE DIELECTRIC WITHSTAND AND GROUND CONTINUITY TESTS ARE SPECIFIED.
ANALOG KILOVOLTMETER WITH 50 VOLT READING RESOLUTION
LINE SAFETY MONITOR
FAILURE DETECTOR
ONE SECOND TIMER
CALIBRATION RESISTOR
1 - PSC GROUND IMPEDANCE TESTER
VOLTAGE MEASUREMENT ACCURACY: 1% (CONTACT IMPEDANCE TYPICALLY 1MV)
RANGE: 0 TO 19.9V
IMPEDANCE CALCULATED: 0 TO 199 M OHMSC
CURRENT MEASUREMENT ACCURACY: 3% OF READING
RANGE : 0 TO 50 AMPS
CALCULATED METHOD: VOLTAGE DROP IS MEASURED AND IMPEDANCE CALCULATED AS PER IEC950,
CLAUSE 2.5.11 AND IEC 601-1 CLAUSE 18F
OPERATING CYCLE : CONTINUOUS TO TEST CURRENTS OF 25A DERATED TO 50% DUTY CYCLE AT 50 25 TO 40 AMPS:
2 MIN 40 TO 50 AMPS: 1 MIN
MAXIMUM CIRCUIT VOLTAGE: 7.9 VOLTS
IMPUTE POWER REQUIREMENTS: 105 TO 125 VOLTS RMS 50\60 HZ
MAXIMUM POWER: 500 WATTS 4.0 A@ 120v
MICRO ELECTRONIC SOLDERING
3 - WELLER WTCP SERIES SOLDERING STATIONS
STATIC DISSAPATIVE HOUSING
MAGNASTAT TEMPERATURE CONTROLS
LOW VOLTAGE CLOSED LOOP DESIGN PROTECTS HEAT
SENSITIVE MATERIALS
ESD SAFE WORK STATIONS FOR MAXIMUM PROTECTION
1 - PACE ST25 WIRE SOLDERER
MISCELLANEOUS ASSEMBLY EQUIPMENT
1 - CHERRY MODEL #G743 AIR RIVET GUN
1 - AVDEL MODEL #0761 AIR RIVET GUN
1 - AVDEL MODEL #07531 AIR RIVET GUN
Home About us Facilities Assembly File Transfers Contact
©
Cado Fabrications |